长光蓄电池型号列表:
CB445
4
4.5
2.7
47
47
101
107
0.62
CB490
4
9
5.4
102
43.5
94.5
100.5
1.12
CB610
6
1
0.6
51
42
51.3
58.3
0.28
CB612
6
1.2
0.72
97
24
52
59
0.30
CB628P
6
2.8
1.68
66
33
97.4
104
0.59
CB630
6
3
1.8
66
32.9
97.4
104
0.59
CB634
6
3.4
2.04
134
34
60
67
0.69
CB638P
6
3.8
2.28
66
33
118.7
125.3
0.76
CB640
6
4
2.4
70
47
101
106
0.80
CB645
6
4.5
2.7
70
47
101
106
0.85
CB650
6
5
3
70
47
101
106
0.89
CB670
6
7
4.2
151
34
94
100
1.25
CB685
6
8.5
5.1
98.5
56
118
118
1.60
CB6100
6
10
6
151
50
95
101
1.72
CB6120
6
12
7.2
151
50
95
101
1.92
CB6120T
6
12
7.2
107.5
70.5
140
140
2.50
CB6120TA
6
12
7.2
107.5
70.5
140
140
2.50
CB6360
6
36
21.6
161
87
163
169
6.20
CB61000
6
100
60
195
170
206
210
17.80
CB62000
6
200
120
322
178
225.5
259.5
35.67
CB827
8
2.7
1.62
134
37
64
70
0.86
CB832
8
3.2
1.92
67.5
48.3
90
90
0.82
CB1207
12
0.7
0.42
96
25
62
62
0.37
CB1212
12
1.2
0.72
97
43
52
59
0.59
CB1212F
12
1.2
0.72
97
48.5
50.5
57
0.56
CB1220
12
2
1.2
178
35
60
67
0.96
CB1220SLM
12
1.8
1.08
150
20
89.5
89.5
0.68
CB1223V
12
2
1.2
182
24
61
61
0.78
CB1229
12
2.9
1.74
79
56
99
105
1.21
CB1230R
12
3
1.8
132
33
98
104.5
1.20
CB1230S
12
3
1.8
66
66
97
104
1.20
CB1230MC
12
3
1.8
98
56
110
110
1.36
CB1234
12
3.4
2.04
134
67
60
67
1.42
CB1240
12
4
2.4
90
70
101
107
1.69
CB1240L
12
4
2.4
195
47
70
74
1.61
CB1245
12
4.5
2.7
90
70
101
107
1.70
CB1250
12
5
3
90
70
101
107
1.76
CB1250HC
12
5
3
84.2
69.2
102
102
1.66
CB1265P
12
6.5
3.9
151
65
94
100
2.23
CB1270
12
7
4.2
151
65
94
100
2.56
CB1270A
12
7
4.2
151
65
94
100
2.46
CB1270PC
12
7
4.2
151
64.5
95
99.5
2.71
CB1280
12
8
4.8
151
65
94
100
2.65
CB1295
12
9.5
5.7
151
65
112
118
3.28
CB12100
12
10
6
151
98
94.5
100
3.39
CB12120
12
12
7.2
151
98
94.5
100
3.85
CB12170
12
17
10.2
181
76
167
167
5.85
CB12240
12
24
14.4
166
175
125
125
8.39
CB12250
12
25
15
166
175
125
125
9.00
CB12250S
12
25
15
166
175
125
125
8.68
CB12280
12
28
16.8
165.5
125
175
175
9.80
CB12330
12
33
19.8
195.5
130
158
179
11.94
CB12350
12
35
21
198
132
170
170
12.60
CB12350S
12
35
21
198
132
170
170
11.92
CB12400
12
40
24
196
165
170
170
14.59
CB12400S
12
40
24
196
165
170
170
13.89
CB12400A
12
40
24
196
165
170
170
暂缺
CB12500
12
50
30
229
138
207
228
16.20
CB12550
12
55
33
229
138
207
228
18.50
CB12650
12
65
39
350
166
174
174
23.66
CB12650S
12
65
39
350
166
174
174
22.70
CB12650A
12
65
39
350
166
174
174
暂缺
CB12680
12
68
40.8
259
168
208
227
23.75
CB12750
12
75
45
259
168
208
227
26.50
CB12900
12
90
54
304
168
208
229
31.18
CB121000A
12
100
60
329
174
214
218
32.94
CB121000B
12
100
60
407
173
209.5
234.5
35.65
CB121000E
12
100
60
329
174
214
218
30.10
CB121000F
12
100
60
407
173
209.5
234.5
33.00
CB121200
12
120
72
407
173
209.5
234.5
38.41
CB121350
12
135
81
345
172
275
278
44.00
CB121500
12
150
90
483
170
241
241
47.48
CB122000A
12
200
120
522
240
218
245
64.10
CB122000B
12
200
120
522
240
218
245
62.57
CB122000
12
200
120
520
260
208
240
73.00
CB122350
12
235
141
547
275
242
242
73.50
CB122550
12
255
153
547
275
242
242
85.00
CB1290MC
12
9
4.5
136
77
117
132
3.16
CB1270MC
12
7
3.5
138
66
87
101
2.27
CGB蓄电池CB12900/12V90AH供应
1)CGB蓄电池在浮充情况时也是长时刻运转情况,其意图就是要坚持蓄电池常常处于充沛充溢情况,但又不能过充电。阀控式密封蓄电池在正常运转情况下,安全阀不该开启,不该有酸雾逸出。
简化了的保护流程在下降了武汉长光蓄电池保护作业量,也进步了蓄电池组的安全危险。即便是依照简化后的流程履行,蓄电池的日常巡检和定时放电仍需求很多的人力、物力才干完结。一年一次的全容量放电的测验密度依然不能做到及时发现电池功用的劣化情况;进一步加大放电实验密度将使蓄电池保护所牵扯的人力、物力投入过大,缺少可操作性;关于现网的数量巨大的蓄电池,缺少体系性的运转功用计算、趋势剖析、预警和质量办理的支撑渠道,保护办理手法落后。保护作业缺少主动性、预防性。
(2)阀控式密封CGB电池的板栅合金、电解液的密度与防酸隔爆式电池均不同,所以其浮充电压一般较防酸隔爆式电池高,而防酸隔爆式电池为坚持电解液的密度梯度小,需求定时进行均衡充电,故两种电流不能并联运转。
(3)阀控式密封蓄电池在运转中为了使电解液上下比较均匀地吸附在隔阂中,在装置时应依据电池板的几许形状放置,长较板的易卧放,短电池板的易立放。
(4)AGM型阀控式密封蓄电池选用吸液率很高的细玻璃纤维做隔板,为缩短氧离子从正电池板到负电池板的距离,均选用紧装置,所以密封蓄电池在运转过程中释放出的热量不宜流失,在装置布放和运转时应充沛考虑蓄电池的散热问题。为使电池常常处于充溢情况和延伸电池的运用寿数,整流设备应依据温度的改动实时调理电池的浮充电压。
(5)阀控式密封CGB蓄电池根本上是不行修理的,但也可商讨在必要时翻开阀门、灌注蒸馏水的问题。
(6)追赶1000Ah的大容量电池一般是选用几个单体电池并联而组成的,有的是内并联,有的是外并联,从运转和保护的视点出发,宜选用外并联办法。
(7)因为防酸隔爆型蓄电池有许多长处,因而在有电池室的情况下仍能够考虑选用。
(8)UPS的后备电池和发电机组的发动电池,其运转情况和准备运转情况应归入集中操控办理,进行盯梢操控。
世界电工学会铅酸蓄电池检测和保护规范IEEE1188-1996中关于长光蓄电池保护规则,关于铅酸蓄电池的保护应做到以下4点:
①实时、的单体蓄电池电压、电池组电流和环境温度的监控;
②每月1~2次的单体蓄电池内阻测验并盯梢长光蓄电池内阻改动趋势;
③每年2次的核对性放电;
④对现场运用时刻追赶2年的蓄电池,应做到每3个月进行一次核对性放电。
该规范在进步了长光蓄电池体系的安稳可靠性的一起,也大大进步了关于蓄电池日常保护的要求,很难在咱们的日常保护中得到充沛的履行。结合咱们本身的实践情况,大部分运转保护作业选用了相对简化的保护流程:
①现网电池浮充电压、浮充电流的日常巡检(每月1次);
②纽带机房CGB蓄电池组核对性放电实验,放出容量的30%~40%(每年1次);
③基站电池全容量放电实验(每年1次);
④发电机发动电池(半年1次)。